IEC C14 Male to European Schuko Female Extension Adapter Cord
Grounded European Socket Interface: The Schuko female receptacle supports grounded European plugs with side earthing contacts, helping maintain protective earth continuity for compatible 250V AC appliances and equipment.
Compact Adapter Cord Layout: The short cable structure gives installers more flexibility than a rigid block adapter, reducing stress on PDU outlets and preventing heavy Schuko plugs from pulling directly on the IEC socket.
Molded Connector and Strain Relief: Both the IEC C14 male plug and Schuko female socket are injection-molded with reinforced cable exits, helping reduce bending stress and conductor fatigue during rack installation, equipment testing, and repeated use.
OEM Configuration Support: Cable length, wire section, jacket type, Schuko socket style, IEC C14 molding, color, cable printing, packaging, and certification route can be customized according to your target equipment and market requirements.
- Product Description
IEC C14 Male to European Schuko Female Adapter Cord for PDU, UPS, and Rack Power Conversion
The IEC C14 Male to European Schuko Female Adapter Cord is designed for IT, laboratory, AV, and power distribution environments where equipment with a Schuko plug needs to be powered from an IEC C13-compatible outlet, UPS, or PDU. The IEC C14 male input connects to standard IEC C13 outlets, while the grounded Schuko female socket provides a European receptacle interface for compatible 250V AC devices. Short. Flexible. Built to reduce mechanical stress compared with rigid plug adapters.

Why Choose Our IEC C14 to Schuko Female Adapter Cord?
Many rack PDUs and UPS systems provide IEC C13 outlets, but the equipment being connected may use a European Schuko plug. This adapter cord bridges that interface gap without forcing buyers to replace the equipment-side plug.
IEC C14 Male Input Converts PDU Power into a Usable Schuko Outlet
The input side uses an IEC 60320 C14 male connector, allowing the cord to mate with IEC C13 outlets commonly found on UPS units, PDUs, power distribution cabinets, and test benches.
For IT buyers, the benefit is direct: European Schuko-plug equipment can be connected to rack power infrastructure without re-terminating cables or relying on unstable universal adapters.
Grounded Schuko Female Socket Supports European Equipment Safety
The output side is a European Schuko female socket with side grounding contacts. When the complete assembly is correctly wired and certified, it can maintain line, neutral, and protective earth continuity from the IEC source to the connected device.
This is important for metal-chassis equipment, lab instruments, AV devices, and other appliances where protective earth connection is required by the final product design.
Short Cable Adapter Reduces Mechanical Load on IEC Outlets
A rigid block adapter can place excessive weight directly on a PDU or UPS outlet, especially when a large Schuko plug is inserted. This cord-style adapter moves that mechanical force away from the socket.
The cable absorbs positioning stress, making it easier to route in crowded racks, behind cabinets, or around equipment where straight plug clearance is limited.
Molded Strain Relief Protects Both Connection Ends
The IEC C14 plug and Schuko female socket are both molded with strain relief sections at the cable exits. These transitions help spread bending force along the jacket instead of concentrating it at the conductor termination point.
For rental AV racks, test equipment, and maintenance benches, this structure helps reduce failures caused by repeated plugging, unplugging, pulling, and cable repositioning.
Complete Product Specifications
| Parameter | Specification |
|---|---|
| Product Name | IEC C14 Male to European Schuko Female Adapter Cord |
| Input Connector | IEC 60320 C14 Male Plug |
| Output Socket | European Schuko Female Socket, Grounded |
| Standard Classification | IEC C14 to Schuko Female Power Adapter Cord |
| Voltage Rating | 250V AC |
| Current Rating | Up to 10A / 16A depending on IEC C14 rating, Schuko socket rating, wire section, and certified configuration |
| Cable Structure | Grounded 3-core cable: line, neutral, and earth |
| Wire Section Options | 3G0.75mm² / 3G1.0mm² / 3G1.5mm² pure copper options |
| Cable Jacket Options | H05VV-F / H05RR-F / H07RN-F depending on indoor, workshop, or heavy-duty use |
| Connector Structure | Molded IEC C14 plug, molded Schuko female socket, integrated strain relief |
| Customization Options | Cable length, wire section, jacket material, socket style, plug molding, color, cable printing, label, packaging |
| Certification Options | CE / VDE / GS / RoHS compliant components depending on target market |
Buyer's Insight: Do not judge this adapter only by the Schuko socket rating. The complete assembly is limited by the lowest-rated component, often the IEC C14 connector, cable section, or certification configuration. If your application needs continuous high load, confirm whether 10A or 16A is actually required before approving the BOM.
Professional Applications You Can Trust
For server racks and UPS installations, PDUs often provide IEC C13 outlets while imported equipment may carry a Schuko plug. This adapter cord lets technicians connect the equipment without cutting the original plug or installing a bulky conversion block inside the rack.
For laboratory benches and test stations, different equipment plug types appear in the same workspace. A short IEC C14 to Schuko adapter cord creates a controlled conversion point while keeping the socket reachable for repeated equipment swaps.
For AV racks and temporary event systems, space behind equipment is limited. The flexible cord structure helps route the Schuko socket away from the PDU face, reducing mechanical strain and making cable labels easier to inspect.
Advanced Safety Features
This is a grounded adapter cord. The earth conductor must be correctly connected from the IEC C14 grounding pin to the Schuko socket grounding contacts. Ground continuity testing should be included in factory inspection.
The final current rating depends on the weakest part of the assembly. Buyers should confirm the IEC C14 connector rating, wire section, Schuko socket rating, cable length, and certification route together before use with heaters, motors, or high-load equipment.
This adapter cord is intended for compatible voltage environments. It changes the connector interface; it does not convert voltage, frequency, or phase. Connected equipment must support the local supply voltage before use.
Manufacturing Excellence
Our factory supports OEM and ODM production for IEC adapter cords, European Schuko socket assemblies, PDU conversion cables, and custom power leads. With 17 years of power cord manufacturing experience, we provide 100% factory electrical testing, including continuity, polarity, ground continuity, insulation resistance, and Hi-Pot testing according to the final product standard and buyer checklist.
Frequently Asked Questions
Q: Does this IEC C14 to Schuko adapter convert voltage?
A: No. This product only converts the physical power connector interface from IEC C14 input to Schuko female output. It does not convert voltage or frequency. The connected device must match the local supply voltage.
Q: Can this adapter cord support 16A?
A: Only if the IEC C14 connector, Schuko socket, wire section, cable length, and certification route are all approved for 16A. Many IEC C14 applications are rated 10A, so buyers should confirm the required current rating before ordering.
Q: Is this adapter cord grounded?
A: Yes, it can be manufactured as a grounded 3-core adapter cord with line, neutral, and earth conductors. Ground continuity from the IEC C14 pin to the Schuko socket contacts should be verified during production testing.
Q: What information is needed for a quotation?
A: Please provide cable length, current rating requirement, wire section, jacket material, Schuko socket style, target certification, order quantity, cable color, labeling, and packaging requirement.
Custom Solutions for Your Business
Cable Length Customization: Produce short adapter lengths for rack PDUs, test benches, and UPS units, or longer lengths for equipment cabinets and AV installations where the Schuko socket must be moved away from the source outlet.
Wire Section & Jacket Selection: Select 3G0.75mm², 3G1.0mm², or 3G1.5mm² copper cable and match it with H05VV-F, H05RR-F, or H07RN-F jacket according to load level and environment.
Connector and Socket Configuration: Schuko socket shape, child safety shutter, indicator light, socket angle, and IEC C14 molding can be adjusted according to the target device and destination market.
Branding & Compliance Matching: Cable printing, molded logo, warning label, packaging label, and certification documentation can be prepared according to your European procurement checklist.
Contact Us
✔ OEM & ODM Support | ✔ IEC to Schuko Adapter Configuration | ✔ 100% Factory Electrical Testing
Ready to discuss your IEC C14 Male to European Schuko Female Adapter Cord requirements? contact us at rhea@szkuncan.net for expert guidance and competitive pricing.



_1788936762601.webp)