European Plug Power Cord with SR Stripped and Tinned Open End
Three visible conductors in brown, blue, and yellow/green support live, neutral, and grounding connection layouts where a grounded cable structure is required.
Molded European plug and open-end strain relief help reduce bending stress at both connection points, improving installation stability during product assembly.
Stripped and tinned wire tips make terminal connection, soldering, or internal wiring faster and cleaner for production-line use.
Cable length, wire gauge, stripping length, tinning length, plug type, jacket material, and packaging can be customized according to project requirements.
- Product Description
European Plug Power Cord with SR Stripped and Tinned Open End
This European Plug Power Cord with SR Stripped and Tinned Open End is designed for OEM products that require a molded European plug on one side and prepared open wires on the other. The visible structure includes a black cable, molded European plug, three color-coded conductors, an open-end strain relief section, and stripped tinned wire tips for direct internal connection.

Why Choose Our European Plug Power Cord with SR Stripped and Tinned Open End?
For equipment manufacturers, this cable is more than a standard plug cord. It is a ready-to-assemble wiring component that helps reduce installation steps, improve connection consistency, and match European plug requirements.
European Molded Plug with Open-End Wiring Supports Direct Equipment Integration
The cord combines a European plug with open-end conductors, allowing the cable to be wired directly into appliances, lighting products, control boxes, or power modules. This structure helps OEM buyers avoid extra adapter parts and makes the cable easier to integrate into product housings.
SR Strain Relief at the Open End Helps Protect the Wire Exit Point
The open end includes a visible SR strain relief section. This feature helps reduce bending stress where the outer cable jacket transitions into individual conductors, which is especially useful when the cable is fixed inside an enclosure or connected near a terminal block.
Stripped and Tinned Wire Tips Improve Assembly Efficiency
The wire ends are visibly stripped and tinned, making them suitable for soldering, terminal insertion, or further internal wiring. For production-line assembly, this preparation can reduce manual wire processing and help keep connection work cleaner and more consistent.
Complete Product Specifications
| Item | Specification |
|---|---|
| Product Type | European plug power cord with SR stripped and tinned open end |
| Input Plug | European plug as shown; exact standard to be confirmed |
| Output End | Open-end wires with SR strain relief |
| Wire End Treatment | Stripped and tinned wire tips |
| Visible Conductors | Brown, blue, and yellow/green wires as shown |
| Grounding Structure | Three-conductor layout visible; final grounding configuration should be confirmed by specification |
| Cable Color | Black as shown; other colors available upon request |
| Cable Length | Custom length available upon request |
| Wire Gauge | Not specified; available according to rated current and application requirement |
| Jacket Material | Common option: PVC; final material to be confirmed by order requirement |
| Rated Voltage / Current | Not specified; should be confirmed according to plug, cable, and equipment load |
| Certifications | Not provided; certification options should be confirmed before quotation |
| Typical Applications | Appliances, lighting fixtures, control boxes, power modules, OEM electrical equipment |
Buyer's Insight: The most important details for this type of cord are not only plug shape and cable length. For production use, the SR position, stripping length, tinning length, conductor color sequence, and wire gauge must match the internal terminal layout. If these details are not confirmed before quotation, the cable may fit electrically but still slow down assembly on the production line.
Professional Applications You Can Trust
For household appliances, buyers often need a European plug cord that can be connected directly to an internal terminal or switch assembly. The stripped and tinned open end helps reduce extra wire preparation during assembly and supports a cleaner connection process.
For lighting fixtures and LED equipment, installation space can be limited inside the housing. The SR strain relief helps manage the transition from the outer cable jacket to individual conductors, reducing stress near the internal wiring point.
For control boxes, power modules, and OEM electrical devices, the three visible conductors allow buyers to plan live, neutral, and grounding connections according to the product design. Final wiring and grounding use should always follow the target equipment standard.
Advanced Safety Features
The molded plug body helps keep the plug structure stable during normal plugging and handling. For power cords used in finished equipment, molding quality and cable matching are important factors for consistent assembly and end-user safety.
The open-end SR design helps protect the cable exit area where bending and pulling may occur during installation. This is especially useful when the cable is fixed inside an enclosure or routed through a narrow opening.
Because this product shows a three-conductor wire layout, the grounding requirement should be checked according to the equipment class and destination market. Buyers should not replace a required grounded cable with a non-grounded design, or use a grounded-looking cable without confirming the internal wiring specification.
Manufacturing Excellence
For OEM power cord orders, manufacturing control should focus on plug molding consistency, correct conductor selection, accurate stripping length, clean tinning, SR molding position, and cable marking. These details directly affect assembly efficiency and product compatibility.
Custom production can be discussed based on drawings, physical samples, or a detailed specification sheet. Final lead time should be confirmed according to cable specification, plug standard, end processing, quantity, and certification requirements.
Frequently Asked Questions
Q: What does “SR stripped and tinned open end” mean?
A: It means the cable has a strain relief section near the open end, and the individual wires are stripped with tinned tips. This preparation helps the wires connect more easily to terminals, switches, or internal soldering points.
Q: Is this cable suitable for grounded equipment?
A: The image shows three visible conductors, including a yellow/green wire commonly used for grounding. However, the final grounding structure, plug standard, and rated specification should be confirmed before use in grounded equipment.
Q: Can the stripping length and tinning length be customized?
A: Yes. Stripping length, tinning length, SR position, and wire preparation can be customized according to the buyer's terminal block, soldering process, or internal wiring layout.
Q: What information is needed for an accurate quotation?
A: Please provide plug type, cable length, wire gauge, rated voltage and current, jacket material, stripping length, tinning length, SR design, certification target, and estimated order quantity.
Custom Solutions for Your Business
Length Customization: Cable length can be adjusted for appliances, lighting fixtures, control boxes, or equipment housings where the power entry position differs by model.
Wire Gauge & Material: Wire gauge and jacket material can be selected according to rated current, flexibility requirement, equipment structure, and target market standard.
Open-End Processing: Stripping length, tinning length, wire separation length, and SR position can be customized to match terminal blocks, soldering points, switches, or internal harness designs.
Plug and Certification Matching: The European plug type, cable marking, and certification path should be confirmed based on destination market, application category, and electrical rating.
Contact Us
✔ Custom SR Open-End Processing | ✔ Wire Gauge Matching | ✔ OEM Power Cord Assembly Support
Please share your required plug type, cable length, wire gauge, rated current, stripping length, tinning length, SR position, and target market. We will help confirm the suitable configuration for your European plug power cord project.
Ready to discuss your European Plug Power Cord with SR Stripped and Tinned Open End requirements? contact us at rhea@szkuncan.net for expert guidance and competitive pricing.